Ozone Analyzer - High Concentration - API-454H

Teledyne

Write a Review
California Regulatory Information

SKU: 007891
SKU:
007891
Condition:
New

Product Overview

Teledyne Gas Monitoring

The Model 454 is a microprocessor ​based gas monitor for measuring mid to high concentrations of ozone in oxygen or air. Available in a standard DIN panel mount configuration with a 4-digit LED display, the compact design provides ease of mounting and installation.​

The 454 series is available in full scale ranges from 0-5% w/w to 0-25% w/w, 0-100 g/Nm3 to 0-500 g/Nm3​, and is factory calibrated in accordance with International Ozone Association standards.  The measurement principle is based on the absorption of UV light at 254nm. As the sample containing ozone flows through the absorption cell, it is exposed to UV light at the 254nm wavelength.  The amount of absorption by ozone is measured by a narrow bandwidth UV detector.


A reference detector measures the lamp output to compensate for changes in light intensity.  This method, using a narrow spectrum UV source and a narrow bandwidth detector, provides excellent performance and stability without requiring additional UV filters.

The 454 series includes temperature and pressure compensations that produce measurements which are normalized to standard conditions. A front panel keypad displays concentration or cell pressure, while LEDs indicate monitoring status. The units employ a state-of-the-art microprocessor design to provide accurate, dependable monitoring of the ozone process.​​

Features

  • Ranges 0-5% w/w to 0-25% w/w
  • DIN panel mount
  • High visibility, 4-digit display
  • Temperature and pressure compensation
  • Units in % w/w or g/Nm3
  • Narrow bandwidth detector eliminates need for UV filters
  • Analog and RS232/485 outputs
  • Status LEDs to monitor performance
  • 316 stainless steel cell

Applications

  • Water Treatment
  • Medical, Food and Beverage​
Optional Accessories Description
 CUV-1 Carrying Case This is an extremely rugged pelican case to carry the API-454 in.
 FM-6-2 Ozone Compatible Flowmeter Designed for specifically for corrosive ozone gas flow-rates, this flow-meter is a precision instrument embodying the inherent simplicity, versatility and economy of the classical variable area meter.
 
 More Information
Weight 4.0000
Electrical 120 - 240 VAC 60 Hz
Dimensions 7.6 x 7.6 x 3.8 inches (19.3 x 19.3 x 9.7 cm)
Warranty 1 Year
Display Digital
Detection Method UV Absorption
Temperature Range 41 to 113°F (5 to 45°C)
Accuracy +/- 1% of Full Scale
Resolution 0.01 Percent By Weight
Supporting Documents User manual and NIST traceable calibration sheet included.
Internal Datalogging No
Display Units g/Nm3, wt%
Comms. Protocol RS-232, RS-485
Zero Drift 1% Full Scale / month (non-cumulative)
LPM Flow Rate 5 LPM
Relays 0
Integrated Pump No
Portability No

What is the maximum amount of tubing I can use to transport ozone to the analyzer?

30 feet of tubing would be the maximum length of tubing recommended.

454 Manual  454 Information Sheet
454 Manual 454 Information Sheet

 

Warranty Information

Seller warrants that all Products will conform to the Specifications and will be free from defects in material workmanship and programming. Claims for Products not complying with this warranty shall be submitted by Buyer no later than 12 months from delivery date to Buyer. Seller shall promptly repair or replace, at its option and expense, non-complying Products. The shipment of non-complying Products by Buyer to Seller, and the return shipment of repaired or replacement Products by Seller to Buyer shall be at Seller's expense, unless it shall be determined that Buyer returned a Product that was in compliance, in which case such cost shall be borne by Buyer and, if paid by Seller, these expenses shall be reimbursed by Buyer within thirty (30) days of notice by Seller. Buyer shall receive a credit for any non-complying Products returned for repair or replacement. All non-complying Products shall be returned to Seller (at its offices or as otherwise instructed) no later than 30 days as of the date the non-compliance of any such Product has been discovered. Seller is NOT responsible for any/all damages suffered to the Products that is caused by the Buyer. Such as but not limited to damage by wrong electrical current, damage through crush or dropping the product, damage through untrained users of Product, damage through improper operations.

California Regulatory Warning

Example Image
Use in unoccupied spaces only.
Health hazard warning: emits ozone.

This product is not CARB Certified (Ozone Emissions for Air Cleaners).
Product Disclaimer: Does not meet California air cleaner regulation requirements; cannot be shipped to California.