Oxygen Concentrator Module - ATF-8

ATF

Write a Review
California Regulatory Information
Price : $1,950.00 $1,950.00
SKU: 007904
SKU:
007904
Condition:
New
Shipping:
Calculated at Checkout
Adding to cart… The item has been added

Product Overview

AirSep AFT-8

A patented single rotary distribution valve built into the ATF module is continuously rotated at low speed by a small motor. The valve is maintenance-free, self-cleaning, insensitive to contamination, and invulnerable to wear. It sequentially directs the flow of compressed air to a group of four sieve beds (adsorption), while at the same time another four beds are purged into the atmosphere though the valve (desorption). The remaining four of the twelve beds are interconnected through the valve to equalize pressure as the sieve beds sequentially transition between adsorption and desorption. The small amplitude pressure swings generated by the ATF’s twelve sieve beds eliminate loud noise pulses, eliminate the need for a pressure regulator, and reduce compressor wear.

Features

  • 8 SCFH Oxygen at 9 PSI from 2.5 CFM compressed air
  • Reliable Oxygen Production
  • Compact and Lightweight
  • Constant Delivery Pressure
  • OEM configuration
 
 More Information
 Weight 9.60 lbs (4.4 kg)
 Dimensions Length: 12.5 in (31.8 cm) Diameter: 8.2 in (20.8 cm)
 Warranty 1 Year
 Flow Rate (CFM) 2.3 CFM
 In Stock Call For Availability
 Max Pressure 9 PSI (0.63 Bar) Max O2 outlet pressure
 Oxygen Connection 1/4-inch Barb
 Integrated Compressor No 2.3 CFM @ 25 PSI required
 Oxygen Flow Rate 3.8 LPM (8.05 SCFH)

 

 System Information
 Input Air Requirements:
 Flow
 Pressure
 
65 LPM (2.3 SCFM)
25 PSI (172 kPa)
 Performance Data:
 Product Flow
 Oxygen Delivery Pressure
 
3.8 LPM (8 SCFH)
9 PSI (62 kPa)
 Product Concentration
90-95%
 Product Dew Point
-100°F (-73°C)
 Dimensions (DxH)
8 x 13 inches
21 x 32 cm
 Weight
9.6 lbs (4.4 kg)
 Physical Connections:
 Compressed Air Inlet
 Product Gas Outlet
 
1/2" ID tubing
1/4" ID tubing
 Ambient Operating Conditions 
  • Locate the oxygen concentrator system in a well-ventilated area that is protected from weather elements.
  • Inside room or enclosure: Temps should remain between 40°F (4°C) and 130°F (54°C) 
  • In storage: Temps should remain between 0°F (-18°C) and 140°F (60°C)
 Control Power Requirements (Single Phase)
120 V / 208-240 V ~ ± 10%, 50 / 60 Hz, 0.025 A or 208-240 V ~ ± 10%, 50 Hz, 0.025A
 Typical Power Consumption
3 W
 Gear Motor
7398 (FMR 1268) / 7383
 Compressed Air Input Requirements
Clean Air (oil-less). Max Temp of 170°F (77°C). Performance Rated at 120°F (49°C).
 Mounting
  • Two Integral Mounting Pads Provided.
  • Toe Clamps (Optional)
  • Vertical Mounting Preferred.
  • Must Be Isolated From Compressor Vibration
 
 
ATF-8 Specifications
ATF-8 Specifications

Warranty Information

Seller warrants that all Products will conform to the Specifications and will be free from defects in material workmanship and programming. Claims for Products not complying with this warranty shall be submitted by Buyer no later than 12 months from delivery date to Buyer. Seller shall promptly repair or replace, at its option and expense, non-complying Products. The shipment of non-complying Products by Buyer to Seller, and the return shipment of repaired or replacement Products by Seller to Buyer shall be at Seller's expense, unless it shall be determined that Buyer returned a Product that was in compliance, in which case such cost shall be borne by Buyer and, if paid by Seller, these expenses shall be reimbursed by Buyer within thirty (30) days of notice by Seller. Buyer shall receive a credit for any non-complying Products returned for repair or replacement. All non-complying Products shall be returned to Seller (at its offices or as otherwise instructed) no later than 30 days as of the date the non-compliance of any such Product has been discovered. Seller is NOT responsible for any/all damages suffered to the Products that is caused by the Buyer. Such as but not limited to damage by wrong electrical current, damage through crush or dropping the product, damage through untrained users of Product, damage through improper operations.

California Regulatory Warning

Example Image
Use in unoccupied spaces only.
Health hazard warning: emits ozone.

This product is not CARB Certified (Ozone Emissions for Air Cleaners).
Product Disclaimer: Does not meet California air cleaner regulation requirements; cannot be shipped to California.