Series B12 transmitters are loop powered instruments that transmit a 4 to 20 mA signal linearly proportional to gas concentration. The system is operated from a 24 VDC power supply, and sufficient for most monitoring applications. 
Alternatively, the unit can operate at 12 VDC, with a reduced output load for applications requiring battery operation. 
 
| Optional Accessories | 
Description | 
|  Display Option | 
External Display options for the B12 Monitor. (NEMA 4X only) | 
|  B12 Calbiration Kit | 
Use the A-23-14 Calibration Kit to calibrate your sensor. (NEMA 4X only) | 
| Ozone Sensors Available | 
Range | 
|  Low | 
0-2 PPM | 
|  Medium | 
0-200 PPM | 
|  High | 
0-1000 PPM | 
Features
 
- Loop powered 4 to 20ma transmitter
 
- Easily integrated into existing control system
 
- Great addition to your data acquisition system
 
- Consider: Wall Mount: LCD optional: Simple Trasmitter: Nema 4x
 
|  More Information | 
|  Weight | 
0.2500 | 
|  Electrical | 
12 - 30 VDC | 
|  Dimensions | 
4" x 4" x 2" (10.2 x 10.2 x 5.1 cm) | 
|  Warranty | 
1 Year | 
|  Display | 
Digital, Optional | 
|  Detection Method | 
Electrochemical | 
|  Temperature Range | 
-22 to 131°F (-30 to 55°C) | 
|  Accuracy | 
+/- 5% | 
|  Resolution | 
0.01 ppm (10 ppb) | 
|  Supporting Documents | 
User Many and NIST Traceable Calibration Sheet included. | 
|  Lead Time | 
3 weeks | 
|  Alarm | 
None | 
|  Response Time | 
10 seconds | 
|  Humidity Range | 
0 to 99% | 
|  Internal Datalogging | 
No | 
|  Display Units | 
ppm | 
|  Relays | 
No | 
|  Multi-Gas Capable | 
No | 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
|  System Specifications | 
| 
  Generally ±5% of value, but limited by available calibration gas accuracy: 
 | 
- 
 ±1% 
 
- 
±0.5% 
 
- Sensor dependent, but generally less than 1% of full scale per month, non-cumulative
 
- Application dependent, but generally less than 3% per month
 
- Loop-powered 4-20 mA, 750 ohms maximum at 24 VDC
 
- 12-30 VDC
 
- None. Optional LCD display available
 
- NEMA 4X Polystyrene Explosion-proof cast iron optional, Class 1, Div. 1, Groups B, C, & D.
 
- Zero and span potentiometers mounted on transmitter circuit board
 
- -30º to +55º C (except oxygen, which is -10º to +55º C)
 
- 7-30 PSIA (0.5-2 Bar)
 
 
 | 
 
| 
  Specfications for Sensor Ranges 
 | 
| 
  Gas 
 | 
 Min Range 
 | 
 Max Range 
 | 
| 
  Acetylene 
 | 
 0-500 ppm 
 | 
 0-2000 ppm 
 | 
| 
  Acid Gases 
 | 
 0-10 ppm 
 | 
 0-200 ppm 
 | 
| 
  Alcohol 
 | 
 0-500 ppm 
 | 
 0-2000 ppm 
 | 
| 
  Ammonia 
 | 
 0-100 ppm 
 | 
 0-2000 ppm 
 | 
| 
  Arsine 
 | 
 0-1000 ppb 
 | 
 0-2000 ppm 
 | 
| 
  Bromine 
 | 
 0-1 ppm 
 | 
 0-200 ppm 
 | 
| 
  Carbon Monoxide 
 | 
 0-100 ppm 
 | 
 0-1000 ppm 
 | 
| 
  Chlorine 
 | 
 0-1 ppm 
 | 
 0-200 ppm 
 | 
| 
  Chlorine Dioxide 
 | 
 0-1 ppm 
 | 
 0-200 ppm 
 | 
| 
  Diborane 
 | 
 0-1000 ppb 
 | 
 0-2000 ppm 
 | 
| 
  Ethylene Oxide 
 | 
 0-20 ppm 
 | 
 0-200 ppm 
 | 
| 
  Fluorine 
 | 
 0-1 ppm 
 | 
 0-200 ppm 
 | 
| 
  Formaldehyde 
 | 
 0-20 ppm 
 | 
 0-200 ppm 
 | 
| 
  Germane 
 | 
 0-1000 ppb 
 | 
 0-2000 ppm 
 | 
| 
  Hydrogen 
 | 
 0-1000 ppm 
 | 
 0-10% 
 | 
| 
  Hydrogen Chloride 
 | 
 0-10 ppm 
 | 
 0-200 ppm 
 | 
| 
  Hydrogen Cyanide 
 | 
 0-20 ppm 
 | 
 0-10 ppm 
 | 
| 
 Hydrogen Fluoride 
 | 
 0-10 ppm 
 | 
 0-200 ppm 
 | 
| 
  Hydrogen Selenide 
 | 
 0-1000 ppb 
 | 
 0-2000 ppm 
 | 
| 
  Hydrogen Sulfide 
 | 
 0-10 ppm 
 | 
 0-500 ppm 
 | 
| 
  Hydrogen Peroxide 
 | 
 0-10 ppm 
 | 
 0-2000 ppm 
 | 
| 
  Iodine 
 | 
 0-1 ppm 
 | 
 0-200 ppm 
 | 
| 
  Nitric Oxide 
 | 
 0-50 ppm 
 | 
 0-500 ppm 
 | 
| 
  Nitrogen Dioxide 
 | 
 0-10 ppm 
 | 
 0-200 ppm 
 | 
| 
  Oxygen 
 | 
 0-5% 
 | 
 0-30% 
 | 
| 
  Ozone 
 | 
 0-1 ppm 
 | 
 0-200 ppm 
 | 
| 
  Phosgene 
 | 
 0-1 ppm 
 | 
 0-100 ppm 
 | 
| 
  Phosphine 
 | 
 0-1000 ppb 
 | 
 0-2000 ppm 
 | 
| 
  Silane 
 | 
 0-10 ppm 
 | 
 0-2000 ppm 
 | 
| 
  Sulfur Dioxide 
 | 
 0-10 ppm 
 | 
 0-200 ppm 
 | 
 
 
| 
 B12 Manual 
 | 
 B12 Specifications 
 | 
 B12 Dimensions 
 | 
  | 
 | 
 |