Outdoor Portable Monitor Pro Kit

Aeroqual

Write a Review
California Regulatory Information


Pricing: Call for Price Today at 888.892.0303

SKU: 012515
SKU:
012515

Product Overview

Series 500 Portable Monitor Specifications (included with Starter & Pro Air Testing Kits)
Measurement units Gas: ppm or mg/m3 | Relative Humidity: % | Temperature °C or °F
Reading functions Instant, minimum, maximum, average
Sensor head Active fan sampling to ensure high accuracy measurements, interchangeable, replaceable, zero and span calibrate sensor headsin the field
Display status indicators Battery, sensor, standby
Sensor calibration Zero and gain calibration
Analog output 0-5 V
Digital interface RS-232 to USB
Data logging Up to 8,188 records(2,706 incl. Temp/RH)
PC data logging Software and data cable supplied. Link data to a specific location and monitor
Clock function Real time
Power supply 12V DC (power adaptor/charger supplied 100-250 V AC)
Rechargeable battery Lithium polymer 12 V DC 2700 mA/h
Enclosure material and rating PC and ABS; IP20 and NEMA 1 equivalent
Size (L x W x D) 195 x 122 x 54 (mm); 7⅝ x 4¾ x 2⅛ (in)(with sensor head)
Weight < 460 g; < 16 oz(with sensor head and battery)
Environmental operating conditions Temperature: -5 °C to 45 °C | Relative Humidity: 0 to 95 % non-condensing
Temperature & Humidity sensor Range -40 °C to 124 °C (-40 °F to 255 °F); Range 0 to 100 % RH
Approvals Part 15 of FCC Rules; EN 50082-1: 1997; EN 50081-1: 1992

 

 

 

Sensor Specifications
gas module Particulate Matter (PM10 & PM2.5) Ozone (O3) Nitrogen Dioxide(NO2) Carbon Monoxide(CO) VOC
Range 0.000 to1.000 mg/m3 0-0.15ppm 0-1ppm 0-25ppm 0-30ppm
Sensor Type* LPC GSS GSE GSE PID
Minimum Detection Limit 0.001 mg/m3 0.001 ppm 0.005 ppm 0.05 ppm 0.01 ppm
Accuracy of Factory Calibration ± (0.002 mg/m3+ 15 % of reading) <±0.005 ppm <±0.02 ppm0-0.2ppm, <± 10% 0.2-1 ppm <±0.5 ppm 0-5ppm, <±10%5-25ppm <±0.2ppm + 10%
Resolution 0.001 mg/m3 0.001ppm 0.001ppm 0.01ppm 0.01ppm
Response Time 5 Seconds 60 Seconds 30 Seconds 60 Seconds 30 Seconds
Temperature 0 to 40°C 0 to 40°C 0 to 40°C 0 to 40°C 0 to 40°C
Relative Humidity 0 to 90% 10 to 90% 15 to 90% 15 to 90% 0 to 95%
STR    
PRO

 

 

Outdoor Portable Monitor Kit at a Glance
Kit / Contents Series 500 Monitor* PM O3 NO2 CO VOC Temp / RH Carry Case
Starter Kit     Small
Pro Kit Large

Warranty Information

Products and parts manufactured by Aeroqual Ltd are warranted against defects and workmanship for a period of one year from ship date.

California Regulatory Warning

Example Image
Use in unoccupied spaces only.
Health hazard warning: emits ozone.

This product is not CARB Certified (Ozone Emissions for Air Cleaners).
Product Disclaimer: Does not meet California air cleaner regulation requirements; cannot be shipped to California.